Proficy Machine Edition Serial Number
Congratulations for purchasing a Proficy* Machine Edition* 8.00 product. After the authorization file serialnumber.plic has been flashed to the M4. Charter Arms Serial Number Database here. Thank you in advance. CPU-Config.jpg' alt='Cimplicity Me' title='Cimplicity Me' />Ge Proficy Proficy Machine Edition. Proficy Machine Edition Download Full Version DOWNLOAD (Mirror #1).
Technical Information
Proficy Machine Edition Help
Specifications
Input Ranges | Current: 0 to 20mA, 4 to 20mA, ±20mA Voltage: ±10V, 0 to 10V, ±5V, 0 to 5V, 1 to 5V | ||||
Backplane Power Requirements | ALG608: ALG616: ALG626: ALG628: | 200 mA maximum @ 5.0V +5% / -2.5%, 200 mA maximum @ 3.3V +5% / -3% 350 mA maximum @ 5.0V +5% / - 2.5%, 200 mA maximum @ 3.3V +5% / - 3% 400 mA maximum @ 5.0V +5% / - 2.5%, 200 mA maximum @ 3.3V +5% / - 3% 260 mA maximum @ 5.0V +5% / - 2.5%, 200 mA maximum @ 3.3V +5% / - 3% | |||
Power Dissipation within Module | IC695ALG608: IC695ALG626: | 2.58Wmaximum;IC695ALG616: 4.50Wmaximum;IC695ALG628: | 4.25 W maximum 2.83 W maximum | ||
Thermal Derating | IC695ALG608 and ALG616: no derating IC695ALG628: no derating ModuleIC695ALG626hasnothermalderatinginvoltagemode.Forthermalderatingfor moduleIC695ALG626incurrentmode,refertopage4. | ||||
Resolution | 24-bit ADC converted to Floating Point or Integer | ||||
Input Data Format | Configurable as floating point IEEE 32-bit or 16-bit integer in a 32-bit field | ||||
Filter Options | 8Hz, 12Hz, 16Hz, 40Hz, 200Hz, 500Hz | ||||
HART Communications | Version 5.0 HART protocol supported on modules IC695ALG626 and IC695ALG628. | ||||
Input Impedance | >100 kvoltage inputs | ||||
Current Input Resistance | 249 ±1% | ||||
Open Circuit Detection time | 1 second maximum | ||||
Overvoltage | ±60 VDC continuous, maximum | ||||
Overcurrent | ±28mA continuous, maximum | ||||
Normal Mode Noise Rejection in dB | At 50Hz | At 60Hz | |||
8 Hz filter | 85 | 85 | |||
12 Hz filter | 85 | 85 | |||
16 Hz filter | 35 | 62 | |||
40 Hz filter | 3 | 6 | |||
200 Hz filter | 0 | 0 | |||
500 HzCrx for chrome. | 0 | 0 | |||
Common Mode Noise Rejection | 120dB minimum @ 50/60 Hz with 8 Hz filter 110dB minimum @ 50/60 Hz with 12 Hz filter | ||||
Channel-Channel DC Crosstalk | -80 dB minimum (single ended mode) -80 dB minimum (differential mode, grounded common) -60 dB minimum (differential mode, floating common) | ||||
Isolation Voltage terminal block to backplane/chassis | Opto-isolated, transformer isolated 250 VAC continuous/1500 VAC for 1 minute |
Analog Module Scan Time (in milliseconds) Configured Filter 8 Hz filter 12 Hz filter 16 Hz filter 40 Hz filter 200 Hz filter 500 Hz filter [with filtering and ratedetection disabled] Configured Filter 8 Hz filter 12 Hz filter 16 Hz filter 40 Hz filter 200 Hz filter 500 Hz filter [with filtering and rate detection disabled] | The module scan for analog signals can consist of up to four acquisition cycles. Each cycle includes a specific set of channels. Total Scan Time depends on the number of acquisition cycles in the scan, the configured filter option, and whether channels are analog or HART. | |||||||
Number of Acquisition Cycles in the Scan (IC695ALG608/616/626/628- Ex and earlier) | ||||||||
1 | 2 | 3 | 4 | |||||
Analog | HART | Analog | HART | Analog | HART | Analog | HART | |
121 | 128 | 241 | 254 | 362 | 380 | 482 | 506 | |
81 | 88 | 161 | 174 | 242 | 260 | 322 | 346 | |
61 | 68 | 121 | 134 | 182 | 200 | 242 | 266 | |
21 | 28 | 41 | 54 | 62 | 80 | 82 | 106 | |
5 | 12 | 9 | 22 | 14 | 32 | 18 | 42 | |
3 | N/A | 5 [6] | N/A | 7 [9] | N/A | 9 [12] | N/A | |
Number of Acquisition Cycles in the Scan (C695ALG608/616/626/628- Fx and later) | ||||||||
1 | 2 | 3 | 4 | |||||
Analog | HART | Analog | HART | Analog | HART | Analog | HART | |
122 | 124 | 247 | 248 | 367 | 375 | 494 | 500 | |
82 | 85 | 164 | 169 | 247 | 255 | 329 | 337 | |
62 | 65 | 127 | 130 | 188 | 191 | 252 | 258 | |
25 | 26 | 50 | 50 | 76 | 72 | 100 | 93 | |
6 | 12 | 12 | 17 | 19 | 24 | 26 | 32 | |
3 | N/A | 7 [6] | N/A | 11 [9] | N/A | 15 [12] | N/A | |
HART Data Scan Time (in seconds) | TheHARTdatascancanconsistofuptofouracquisitioncycles(similarbutasynchronoustothe analogscantime).Eachcycleincludesaspecificsetofchannels.TotalHARTscantimedepends onthenumberofchannelsenabledforHARTwithinaspecificsetofchannels,numberofretries, enabling/disabling of slot variables, and use and configuration settings of pass-thru commands. | |||||||
Channels in Group Enabled for HART: | Each HART Data channel updates every: | |||||||
One | 0.7 second (typical) | |||||||
Two | 1.9 seconds (typical) | |||||||
Three | 3.0 seconds (typical) | |||||||
Four | 4.0 seconds (typical) | |||||||
Calibrated Accuracy In the presence of severe RF interference (IC 801-3, 10V/M), accuracy may be degraded by ±1.5% of range. | From 13°C – 33°C: ±5V, ±10V, ±20 mA:0.05% ofrange. 0 to 10V, 0 to 5V, 1 to 5V, 0 to 20 mA: 0.1% of range. 4 to 20 mA:0.125% ofrange. | |||||||
From 0°C – 60°C: 0 to 10V, 0 to 5V, 1to5V:0.2% ofrange. 0 to 20 mA:0.25% ofrange. 4 to 20 mA:0.3125% ofrange. ±5V, ±10V: 0.1%±20mA:0.125% ofrange. | ||||||||
Calibration Interval | 12 months typical to meet accuracy specifications over time. Offset can be applied as a periodic calibration adjustment. |