Congratulations for purchasing a Proficy* Machine Edition* 8.00 product. After the authorization file serialnumber.plic has been flashed to the M4. Charter Arms Serial Number Database here. Thank you in advance. CPU-Config.jpg' alt='Cimplicity Me' title='Cimplicity Me' />Ge Proficy Proficy Machine Edition. Proficy Machine Edition Download Full Version DOWNLOAD (Mirror #1).

  1. Proficy Machine Edition Help

Technical Information

ProficyProficy machine edition price

Proficy Machine Edition Help

Proficy

Specifications

Input Ranges

Current: 0 to 20mA, 4 to 20mA, ±20mA Voltage: ±10V, 0 to 10V, ±5V, 0 to 5V, 1 to 5V

Backplane Power Requirements

ALG608: ALG616: ALG626:

ALG628:

200 mA maximum @ 5.0V +5% / -2.5%,

200 mA maximum @ 3.3V +5% / -3%

350 mA maximum @ 5.0V +5% / - 2.5%,

200 mA maximum @ 3.3V +5% / - 3%

400 mA maximum @ 5.0V +5% / - 2.5%,

200 mA maximum @ 3.3V +5% / - 3%

260 mA maximum @ 5.0V +5% / - 2.5%,

200 mA maximum @ 3.3V +5% / - 3%

Power Dissipation within Module

IC695ALG608: IC695ALG626:

2.58Wmaximum;IC695ALG616:

4.50Wmaximum;IC695ALG628:

4.25 W maximum

2.83 W maximum

Thermal Derating

IC695ALG608 and ALG616: no derating IC695ALG628: no derating

ModuleIC695ALG626hasnothermalderatinginvoltagemode.Forthermalderatingfor moduleIC695ALG626incurrentmode,refertopage4.

Resolution

24-bit ADC converted to Floating Point or Integer

Input Data Format

Configurable as floating point IEEE 32-bit or 16-bit integer in a 32-bit field

Filter Options

8Hz, 12Hz, 16Hz, 40Hz, 200Hz, 500Hz

HART Communications

Version 5.0 HART protocol supported on modules IC695ALG626 and IC695ALG628.

Input Impedance

>100 kvoltage inputs

Current Input Resistance

249 ±1%

Open Circuit Detection time

1 second maximum

Overvoltage

±60 VDC continuous, maximum

Overcurrent

±28mA continuous, maximum

Normal Mode Noise Rejection in dB

At 50Hz

At 60Hz

8 Hz filter

85

85

12 Hz filter

85

85

16 Hz filter

35

62

40 Hz filter

3

6

200 Hz filter

0

0

500 HzCrx for chrome.

0

0

Common Mode Noise Rejection

120dB minimum @ 50/60 Hz with 8 Hz filter 110dB minimum @ 50/60 Hz with 12 Hz filter

Channel-Channel DC Crosstalk

-80 dB minimum (single ended mode)

-80 dB minimum (differential mode, grounded common)

-60 dB minimum (differential mode, floating common)

Isolation Voltage terminal block to

backplane/chassis

Opto-isolated, transformer isolated

250 VAC continuous/1500 VAC for 1 minute

Analog Module Scan Time (in milliseconds)

Configured Filter

8 Hz filter

12 Hz filter

16 Hz filter

40 Hz filter

200 Hz filter

500 Hz filter [with filtering and ratedetection disabled]

Configured Filter

8 Hz filter

12 Hz filter

16 Hz filter

40 Hz filter

200 Hz filter

500 Hz filter

[with filtering and rate

detection disabled]

The module scan for analog signals can consist of up to four acquisition cycles. Each cycle includes a specific set of channels. Total Scan Time depends on the number of acquisition cycles

in the scan, the configured filter option, and whether channels are analog or HART.

Number of Acquisition Cycles in the Scan (IC695ALG608/616/626/628- Ex and earlier)

1

2

3

4

Analog

HART

Analog

HART

Analog

HART

Analog

HART

121

128

241

254

362

380

482

506

81

88

161

174

242

260

322

346

61

68

121

134

182

200

242

266

21

28

41

54

62

80

82

106

5

12

9

22

14

32

18

42

3

N/A

5

[6]

N/A

7

[9]

N/A

9

[12]

N/A

Number of Acquisition Cycles in the Scan (C695ALG608/616/626/628- Fx and later)

1

2

3

4

Analog

HART

Analog

HART

Analog

HART

Analog

HART

122

124

247

248

367

375

494

500

82

85

164

169

247

255

329

337

62

65

127

130

188

191

252

258

25

26

50

50

76

72

100

93

6

12

12

17

19

24

26

32

3

N/A

7

[6]

N/A

11

[9]

N/A

15

[12]

N/A

HART Data Scan Time (in seconds)

TheHARTdatascancanconsistofuptofouracquisitioncycles(similarbutasynchronoustothe analogscantime).Eachcycleincludesaspecificsetofchannels.TotalHARTscantimedepends onthenumberofchannelsenabledforHARTwithinaspecificsetofchannels,numberofretries,

enabling/disabling of slot variables, and use and configuration settings of pass-thru commands.

Channels in Group Enabled for HART:

Each HART Data channel updates every:

One

0.7 second (typical)

Two

1.9 seconds (typical)

Three

3.0 seconds (typical)

Four

4.0 seconds (typical)

Calibrated Accuracy In the presence of severe RF interference

(IC 801-3, 10V/M),

accuracy may be degraded by ±1.5% of range.

From 13°C – 33°C:

±5V, ±10V, ±20 mA:0.05% ofrange.

0 to 10V, 0 to 5V, 1 to 5V, 0 to 20 mA: 0.1% of range.

4 to 20 mA:0.125% ofrange.

From 0°C – 60°C:

0 to 10V, 0 to 5V, 1to5V:0.2% ofrange.

0 to 20 mA:0.25% ofrange.

4 to 20 mA:0.3125% ofrange.

±5V, ±10V: 0.1%±20mA:0.125% ofrange.

Calibration Interval

12 months typical to meet accuracy specifications over time. Offset can be applied as a periodic calibration adjustment.